Flowline UG01-0001-40 Liquid Level Sensor | Liquid Level Control
Flowline UG01-0001-40 Liquid Level Sensor for Industrial Liquid Level Monitoring, Tank Automation and Process Control
Use Flowline UG01-0001-40 Liquid Level Sensor for industrial level applications. Confirm range, mounting, output and process compatibility before
Flowline UG01-0001-40 Liquid Level Sensor
The Flowline UG01-0001-40 is a Reflective Ultrasonic Multi-Function Liquid Level Sensor Transmitter Reflective Ultrasonic Multi-Function Liquid Level Sensor Transmitter,4mA, 20mA, 21mA, 22mA, hold last, WebCal PC Windows USB 2.0 designed for industrial liquid-level measurement, monitoring or control applications. Use the exact model number when comparing replacement or new-installation requirements, because connection, output, range and enclosure options can vary across Flowline configurations.
Key Product Details
- Resolution: =0
- Dead Band: maximizes tank filling capacity
- Beam Width: for applications with limited space
- Material: PVDF
- Process Mount: -0001: 2" NPT, -0011: 2" G
- Supply Voltage: 14-28 VDC
- Enclosure Rating: Type 6P (IP68)
- Memory: Non-volatile
- Output: and four relays, and is configured via our WebCal software
- Series: UG01
Before purchase, compare the complete model code with the application requirements. Check tank dimensions, process connection, wetted materials, power or signal needs, measurement range and environmental conditions where those values apply. This helps prevent selecting a similar-looking Flowline model with a different configuration.
Application and Installation Planning
For replacement work, record the existing model number and wiring or mounting arrangement before removal. For new projects, review the documented installation guidance and leave adequate clearance around the sensing area. Commission the device using the applicable Flowline instructions and verify the output or switching behavior before returning the process to normal operation.
Why Model Verification Matters
For maintenance teams, integrators and OEM users searching for Flowline UG01-0001-40, the model-specific identification makes it easier to match the product to a documented Flowline level-control system without relying on appearance alone.
| Part No | UG01-0001-40 |
|---|---|
| Brand | Flowline |
| Product Type | Liquid Level Sensor |
| Series | UG01 |
| Range | 1.5" to 4.9' (3.8cm to 1.5m) |
| Accuracy | 0.125" (3mm) |
| Resolution | 0.019" (0.5mm) |
| Dead band | 1.5" (3.8cm) |
| Beam width | 2" (5cm) |
| Configuration | WebCal® PC Windows® USB® 2.0 |
| Memory | Non-volatile |
| Supply voltage | 14-28 VDC |
| Max. consumption | 0.5W |
| Loop resistance | 500 ohms @ 24 VDC |
| Signal output | 4-20mA, two-wire |
| Signal invert | 4-20mA or 20-4mA |
| Signal fail-safe | 4mA, 20mA, 21mA, 22mA, hold last |
| Contact type | (4) SPST relays |
| Contact rating | 60 VA, 1A maximum |
| Contact fail-safe | Open, closed, hold last |
| Contact hysteresis | Selectable |
| Process temp. | F: -40° to 176°, C: -40º to 80° |
| Temp. comp. | Automatic |
| Ambient temp. | F: -31° to 140°, C: -35° to 60° |
| Pressure | 30 psi (2 bar) |
| Enclosure rating | Type 6P (IP68) |
| Encl. material | Polypropylene |
| Transducer type | Reflective |
| Transducer mat. | Polyvinylidene fluoride |
| Cable jacket mat | Polyurethane |
| Cable type | 9-conductor, shielded |
| Cable length | 48" (1.2m) |
| Process mount | -0001: 2" NPT, -0011: 2" G |
| Mount gasket | -0001: N/a, -0011: Viton |
| Classification | General purpose |
| Approval | UL 61010-1 |
| Compliance | CE, RoHS |