Flowline LU81-5161 Product Overview
The Flowline LU81-5161 is a Ultrasonic Level Transmitter, Sensor range 5 designed for industrial liquid-level measurement, monitoring or control applications. Use the exact model number when comparing replacement or new-installation requirements, because connection, output, range and enclosure options can vary across Flowline configurations.
What to Confirm Before Ordering
- Exact Flowline model: LU81-5161
- Required measurement or switching function
- Process connection and mounting arrangement
- Electrical and output requirements
- Process-fluid and environmental compatibility
Available Product Information
- Range: s from 9
- Accuracy: +/- 0
- Resolution: LU80: 0
- Dead Band: LU80: 4
- Beam Width: for applications with limited measurement space
- Material: PVDF
- Process Mount: G (Metric), Mount gasket Viton, Temp
- Supply Voltage: 12-28 VDC
- Enclosure Rating: NEMA 4X (IP65)
- Memory: Non-volatile
Practical Use and Maintenance
For replacement work, record the existing model number and wiring or mounting arrangement before removal. For new projects, review the documented installation guidance and leave adequate clearance around the sensing area. Commission the device using the applicable Flowline instructions and verify the output or switching behavior before returning the process to normal operation.
Before purchase, compare the complete model code with the application requirements. Check tank dimensions, process connection, wetted materials, power or signal needs, measurement range and environmental conditions where those values apply. This helps prevent selecting a similar-looking Flowline model with a different configuration.
For maintenance teams, integrators and OEM users searching for Flowline LU81-5161, the model-specific identification makes it easier to match the product to a documented Flowline level-control system without relying on appearance alone.
| Part No | LU81-5161 |
|---|---|
| Brand | Flowline |
| Product Type | Ultrasonic Level Transmitter |
| Range | LU80: 4in to 9.8ft (10cm to 3m) / LU81: 8in to 18.0ft (20cm to 5.5m) / LU83: 8in to 26.2ft (20cm to 8m) / LU84: 12in to 32.8ft (30cm to 10m) |
| Accuracy | +/- 0.2% of range |
| Resolution | LU80: 0.019 |
| Dead band | LU80: 4 |
| Beam width | LU80: 2 |
| Configuration | Push button |
| Memory | Non-volatile |
| Display type | LCD, 6-digit |
| Display units | Inch, cm and percent |
| Supply voltage | 12-28 VDC |
| Loop resist. | 500 Ohms @ 24 VDC |
| Signal output | 4-20 mA, two-wire |
| Signal invert | 4-20 mA, 20-4 mA |
| Signal fail-safe | 4mA, 20mA, 21mA, 22mA or hold last |
| Process temp. | F: -4° to 140° C: -20° to 60° |
| Temp. comp. | Automatic |
| Ambient temp. | F: -31° to 140° C: -35° to 60° |
| Pressure | MWP = 30 psi (2 bar) |
| Enclosure rating | NEMA 4X (IP65) |
| Enclosure mat. | Polycarbonate |
| Encl. hardware | Brass & stainless |
| Enclosure vent | Water tight membrane |
| Conduit entrance | Dual, 1/2 |
| Trans. material | PVDF |
| Process mount | LU80: 1 |
| Mount gasket | Viton |
| Classification | General purpose |
| Compliance | CE, RoHS |