Flowline US06-0001-01 Level Sensor | Liquid Level Control System

Flowline US06-0001-01 Level Sensor | Liquid Level Control System

Flowline US06-0001-01 Level Sensor for Industrial Liquid Level Monitoring, Tank Automation and Process Control
SKU:US06-0001-01
Model Number: US06
$1160.000

Use Flowline US06-0001-01 Level Sensor for industrial level applications. Confirm range, mounting, output and process compatibility before purchase.


WHERE TO BUY?
Overview
Specification
Documents
Overview

Flowline US06-0001-01: Selection and Application Guide

The Flowline US06-0001-01 is a Reflective Ultrasonic Liquid & Solids Level Sensor Transmitter, 8" to 19 designed for industrial liquid-level measurement, monitoring or control applications. Use the exact model number when comparing replacement or new-installation requirements, because connection, output, range and enclosure options can vary across Flowline configurations.

Specification Snapshot

  • Range: 8" to 19
  • Accuracy: &plusmn 0
  • Resolution: =0
  • Dead Band: 8" (20
  • Beam Width: for applications with limited space
  • Material: PVDF
  • Process Mount: 06-0001: 2" NPT, 06-0011: 2" G, 12-0001: 3" NPT, 12-0011: 3"
  • Supply Voltage: 14-28 VDC
  • Enclosure Rating: Type 4X (IP66)
  • Memory: Non-volatile

Customer Selection Notes

Before purchase, compare the complete model code with the application requirements. Check tank dimensions, process connection, wetted materials, power or signal needs, measurement range and environmental conditions where those values apply. This helps prevent selecting a similar-looking Flowline model with a different configuration.

Installation and Commissioning

For replacement work, record the existing model number and wiring or mounting arrangement before removal. For new projects, review the documented installation guidance and leave adequate clearance around the sensing area. Commission the device using the applicable Flowline instructions and verify the output or switching behavior before returning the process to normal operation.

Maintenance Considerations

During service, inspect mounting threads, seals, wiring, cable entries and nearby process hardware as applicable. If the product is being replaced because of unstable readings or switching, verify the installation conditions before assuming the instrument itself is the only cause.

For maintenance teams, integrators and OEM users searching for Flowline US06-0001-01, the model-specific identification makes it easier to match the product to a documented Flowline level-control system without relying on appearance alone.

Specification
Part NoUS06-0001-01
BrandFlowline
Product TypeLevel Sensor
SeriesUS06
Range8" to 19.6' (20cm to 6m)
Accuracy&plusmn 0.2% of range
Resolution0.079" (2mm)
Dead band8" (20.3cm)
Beam width3" (7.6cm)
ConfigurationPush button or WebCal &reg PC Windows &reg USB &reg 2.0
MemoryNon-volatile
Display typeLCD, 6-digit
Display unitsInch, cm or percent
Supply voltage14-28 VDC
Loop resistance500 ohms @ 24 VDC
Signal output4-20mA, two-wire
Signal invert4-20mA or 20-4mA
Signal fail-safe4mA, 20mA, 21mA, 22mA, hold last value
Process temp.F: -40°  to 176°, C: -40° to 80°
Temp. comp.Automatic
Ambient temp.F: -40° to 176°, C: -40° to 80°
Pressure30 psi (2 bar)
Enclosure ratingType 4X (IP66)
Encl. materialAluminum
Enclosure ventWater tight membrane
Conduit entrance1/2" NPT
Transducer typeReflective
Transducer mat.Polyvinylidene fluoride
Process mount06-0001: 2" NPT, 06-0011: 2" G, 12-0001: 3" NPT, 12-0011: 3" G
Mount gasket-0001: N/a, -0011: Viton&reg
ClassificationIntrinsically safe
ApprovalsCSA for Canada: Class I, Division 1, Groups A, B, C and D T4; Class II, Division 1, Groups E, F and G T4; Class III, T135C; Ex ia IIC T4 Ga; Ex ia IIIC, T135C Da; CSA for U.S.: Class I, Division 1, Groups A, B, C and D T4; Class II, Division 1, Groups E, F and G T4; Class III, T135C; Class I, Zone 0, IIC AEx ia T4 Ga; Class II, Zone 20, IIC AEx ia, T135C Da
Entity parametersInstall per control drawing #600820
Power & Return2-pin quick connect terminal block
WebCal Connect.2-pin quick connect terminal block
Display Connect.5-pin plug and socket
ComplianceCE, RoHS
Documents

Related Documents List