Flowline UG01-0011-40 Reflective Ultrasonic Multi-Function Liquid Level Sensor Transmit UG01-0011-40

Flowline UG01-0011-40 Reflective Ultrasonic Multi-Function Liquid Level Sensor Transmit UG01-0011-40

Ultrasonic Level Transmitter of Flowline with material PVDF
SKU:UG01-0011-40
Model Number: UG01
$0.000

Flowline UG01-0011-40 Reflective Ultrasonic Multi-Function Liquid Level Sensor Transmitter,4mA, 20mA, 21mA, 22mA, hold last, WebCal PC Windows USB 2.0


WHERE TO BUY?
Overview
Specification
Accessories
Overview
APPLICATION:

The general purpose reflective ultrasonic multi-function level transmitter provides continuous level measurement up to 9.8' (3m) with a 4-20 mA analog signal output and four relays, and is configured via our WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Each relay can be configured for alarm, automatic fill or empty functions. Select this sensor for small tanks with non-foaming and mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps.

FEATURES:
  • Offered in 1.5m (4.9') and 3m (9.8') measurement ranges
  • Fail-safe diagnostics with selectable relay and signal outputs
  • Narrow 2" (5cm) beam width for applications with limited space
  • Corrosion resistant PVDF transducer and compact PP enclosure
  • Short 1.5" (3.8cm) dead band maximizes tank filling capacity
  • Automatic temperature compensation from -40° to 80° C.
  • Four programmable relays with embedded level control logic
    • 1 pump or valve with 3 alarms
    • 2 pumps lead-lag with 2 alarms
    • 2 pumps duplexing with 2 alarms
    • 4 independent switch point alarms
REFLECTIVE:

Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45° reflector, delivering reliable level measurement. Thanks gravity.

Specification
SeriesUG01
Range1.5" to 4.9' (3.8cm to 1.5m)
Accuracy0.125" (3mm)
Resolution0.019" (0.5mm)
Dead band1.5" (3.8cm)
Beam width2" (5cm)
ConfigurationWebCal&reg PC Windows&reg USB&reg 2.0
MemoryNon-volatile
Supply voltage14-28 VDC
Max. consumption0.5W
Loop resistance500 ohms @ 24 VDC
Signal output4-20mA, two-wire
Signal invert4-20mA or 20-4mA
Signal fail-safe4mA, 20mA, 21mA, 22mA, hold last
Contact type(4) SPST relays
Contact rating60 VA, 1A maximum
Contact fail-safeOpen, closed, hold last
Contact hysteresisSelectable
Process temp.F: -40° to 176°, C: -40º to 80°
Temp. comp.Automatic
Ambient temp.F: -31° to 140°, C: -35° to 60°
Pressure30 psi (2 bar)
Enclosure ratingType 6P (IP68)
Encl. materialPolypropylene
Transducer typeReflective
Transducer mat.Polyvinylidene fluoride
Cable jacket matPolyurethane
Cable type9-conductor, shielded
Cable length48" (1.2m)
Process mount-0001: 2" NPT, -0011: 2" G
Mount gasket-0001: N/a, -0011: Viton
ClassificationGeneral purpose
ApprovalUL 61010-1
ComplianceCE, RoHS
Accessories
LM52-2890 Flowline Fittings LM52-2890
LM52-3890 Flowline Fittings LM52-3890
LM52-2400 Flowline Fittings LM52-2400
LM52-2410 Flowline Fittings LM52-2410
LM52-2800 Flowline Installation Fittings LM52-2800
LM52-2810 Flowline Fittings LM52-2810
Flowline LM52-3800
Flowline LM52-3810