LU30-5064 Flowline Ultrasonic Level Transmitter LU30-5064
Ultrasonic Level Transmitter of Flowline with Resolution 0.125in (3mm)
Flowline EchoTouch Ultrasonic Level Transmitter, Process mount G (Metric), Signal output 4-20 mA, sinking, Non-volatile Memory, Supply Voltage 14-36 VDC
The general purpose 3-wire ultrasonic level transmitter provides continuous level measurement up to 24.5' (7.4m) with a 4-20 mA signal output, and is configured via the integral push button display module. The level sensor has one 10A relay which can be configured on a single set point (high level alarm or low level alarm) or latched on two set points for automatic fill or empty with fail-safe logic. This non-contact liquid level sensor is well suited for corrosive, ultrapure, sticky or dirty liquids, and is widely selected for bulk storage and day tank level applications.
- Level measurement up to 24.5' (7.4m) with 1 programmable relay
- Configuration is simple via integral push button display module
- LED digital display indicates level in inches or centimeters
- Programmable relay for alarm or automatic fill-empty control
- Polypropylene enclosure rated NEMA 4X with rugged PVDF transducer
| Range | 6in to 24.5ft (15cm to 7.4m) |
|---|---|
| Accuracy | +/- 0.25% of range |
| Resolution | 0.125in (3mm) |
| Dead band | 6in (15cm) |
| Beam width | 8° Conical |
| Configuration | Push button |
| Memory | Non-volatile |
| Display type | LED, 4-digit |
| Display units | Inch or cm |
| LED indication | Relay status |
| Supply voltage | 14-36 VDC |
| Consumption | 200mA maximum |
| Signal output | 4-20 mA, three-wire |
| Signal invert | 4-20 mA, 20-4 mA |
| Current flow | Sourcing or sinking |
| Contact type | SPDT relay, latching |
| Contact rating | 250 VAC @ 10A |
| Contact logic | Single point: alarm / Two point: latching |
| Contact fail-safe | Reverts to safe state during echo-loss |
| Process temp. | F: -4° to 140°, C: -20° to 60° |
| Temp. comp. | Automatic |
| Ambient temp. | F: -40° to 140°, C: -40° to 60° |
| Pressure | 30 psi (2 bar) @25° C, derated @1.667 psi (.113 bar) per °C above 25° C. |
| Enclosure rating | NEMA 4X (IP65) |
| Enclosure mat. | PP, UL94VO |
| Conduit entrance | Single, 1/2in NPT |
| Cable length | 9in (22cm) |
| Cable type | Power & signal: 3-conductor / Relay: 3-conductor |
| Cable jacket | Vinyl |
| Trans. material | PVDF |
| Process mount | 2in NPT (2in G) |
| Mount gasket | Viton |
| Classification | General purpose |
| Compliance | CE |