LR25-0310-60 Flowline Radar Level Transmitters LR25-0310-60

LR25-0310-60 Flowline Radar Level Transmitters LR25-0310-60

Radar Level Transmitters of Flowline with Frequency 6.3 GHz.
SKU:LR25-0310-60
Model Number: LR25-0310-X0
$0.000

Flowline LR25-0310-60 Radar Level Transmitters. Flange size 6in ANSI, Range 12in to 114.8in (30cm to 35m), Supply voltage 16-26 VDC


WHERE TO BUY?
Overview
Specification
Overview
Application

The general purpose 6.3 GHz. pulse radar level transmitter provides continuous level measurement up to 114.8' (35m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical and petroleum storage or process applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for harsh application conditions with corrosive or low dielectric media, heavy surface foam or agitation, higher pressure, steam, condensation or vapor, and installation in a flange fitting. Due to the wider beam angle, special attention should be given to ensure that the sensor is located with unobstructed measurement space.

Fields of Application:
  • 316 L antenna with PTFE inner shield for corrosive media
  • Simple configuration via integral push button display module
  • 6.3 GHz. pulse radar is unaffected by most foam and agitation
  • 12"(30cm) dead band enables utilization of the entire tank
  • LCD displays level in feet or meters with percent of span bar
  • Optional display mode indicates the echo signal return curve
  • Auto-temperature compensation for accurate measurement
  • Fail-safe diagnostics with selectable signal fail-safe outputs
  • Recognition, storage and rejection of false echo signal returns
  • Rugged IP67 aluminum enclosure with polycarbonate window
Specification
Range12in to 114.8in (30cm to 35m)
Frequency6.3 GHz.
Accuracy+/- 10mm
Dead band12
Beam angle20°
ConfigurationPush button
MemoryNon-volatile
Display typeLCD, dot matrix
Display unitsFeet and meters
Display barPercent of span
Display graphEcho signal curve
Supply voltage16-26 VDC
Max. consumption22.5 mA
Signal output4-20 mA, two-wire
Signal invert4-20 mA, 20-4 mA
Signal fail-safe3.9 mA, 20.5 mA, 22 mA
Process temperatureF: -40° to 266°, C: -40° to 130°
Temperature comp.Automatic
Storage TemperatureF: -40° to 176°, C: -40° to 80°
Pressure-14.5 to 580 psi (-1 to 40 bar)
Enclosure ratingIP67
Encloser materialAluminum w/silicone gasket
Encloser window mat.Polycarbonate
Conduit entrance1/2
Antenna material316 L w/PTFE inner shield
Process mount40: 4
ClassificationGeneral purpose
CertificationcTUVus, FCC
ComplianceCE, CRN, RoHS