Flowline DL34-11 Ultrasonic Level Transmitter DL34-11

Flowline DL34-11 Ultrasonic Level Transmitter DL34-11

DL34 Series Multi-Function Ultrasonic Level Transmitter of Flowline with Resolution 0.079, Process mount G (Metric), Supply voltage 24 VDC (loop)
SKU:DL34-11
Model Number: DL34-XX
$950.000

DL34-11 Flowline Multi-Function Ultrasonic Level Transmitter. Accuracy ±0.2% of range, Range 18.0ft (5.5m), Dead band 8 in (20cm), Non-volatile Memory.


WHERE TO BUY?
Overview
Specification
Documents
Accessories
Overview
DL34 Series Ultrasonic Level Transmitter :
Application

The general purpose ultrasonic level transmitter provides continuous level measurement up to 18.ft (5.5m) with a 4-20 mA signal output, and is configured via our free Webcal software. The level sensor has 4 programmable relays with selectable hysteresis and fail-safe logic. The embedded level controller can lower cost by replacing external control hardware. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is widely selected for day tank, skid, IBC, sump and process tank level applications.

Fields of Application:
  • Level detection, switch and control functions up to 18.0ft (5.5m)
  • Configuration is fast and easy via WebCal software and USB adapter
  • Narrow 3'' beam width and short 8'' dead band optimized for small tanks
  • Four programmable relays for switch, pump or valve control and fail-safety
    • 1 pump or valve with 3 alarms
    • 2 pumps (lead-lag) with 2 alarms
    • Pumps (duplexing) with 2 alarms
    • Independent switch point alarms
  • PVDF transducer and 6P polycarbonate enclosure for corrosive liquids
  • Automatic temperature compensation for accurate measurement
Compatible Products:

LI25, LI55, LI90, LC52.

Specification
Range18.0ft (5.5m)
Accuracy±0.2% of range
Resolution0.079
Dead Band8 in (20cm)
Beam Width3in (7.6cm)
ConfigurationWebCal PC Windows USB 2.0
MemoryNon-volatile
Supply Voltage24 VDC (loop)
Consumption0.5W
Loop Resistance400Ω max
Signal Output4-20 mA, two-wire
Signal Invert4-20 mA or 20-4 mA
Signal Fail-safe4 mA, 20 mA, 21 mA, 22 mA or hold last
Contact TypeSPST relays
Contact Rating60 VA, 1A maximum
Contact fail-safePower loss: Hold last Echo loss: Open, close or hold last
HysteresisSelectable
Process Temperature20°F to 140°F (-7°C to 60°C)
Temperature CompAutomatic
Ambient Temperature-31°F to 140°F (-35°C to 60°C)
PressureMWP = 30 PSI (2 bar)
Enclosure RatingType 6P, encapsulated, corrosion resistant & submersible
Enclosure MaterialPolycarbonate
Trans MaterialPVDF
Cable Jacket MaterialPolyurethane
Cable Type9-conductor, shielded
Cable Length48in (1.2m)
Process Mount2in NPT (2in G)
Mount GasketViton
ClassificationGeneral purpose
ComplianceCE, RoHS
ApprovalscFMus
TypeLevel Transmitter
SeriesDL34
Documents

Related Documents List

Accessories
LM52-2400 Flowline Fittings LM52-2400
LM52-2800 Flowline Installation Fittings LM52-2800
LM52-2410 Flowline Fittings LM52-2410
LM52-3410 Flowline Fittings LM52-3410
LM52-2810 Flowline Fittings LM52-2810
LM52-2890 Flowline Fittings LM52-2890
LM50-1001 Flowline Fittings LM50-1001