DL24-00 Flowline Ultrasonic Level Transmitter DL24-00
Level Transmitter of Flowline with Polycarbonate Enclosure Material
Flowline DL24-00 EchoPod Ultrasonic liquid level sensor, Process mount NPT (US), 9.8ft (3m) sensing range, 4-20 mA or (4) SPST relays, 14-28 VDC operating voltage, 1" male NPT with Viton gasket
The general purpose ultrasonic level transmitter provides continuous level measurement up to 9.8 inch (3m) with a 4-20 mA signal output, and is configured via our free Webcal software.with 1inch NPT Viton gasket The level sensor has 4 programmable relays with selectable hysteresis and fail-safe logic. The embedded level controller can lower cost by replacing external control hardware. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids, and is widely selected for day tank, skid, IBC, sump and process tank level applications.
- Level detection, switch and control functions up to 9.8 inch (3m)
- Configuration is fast and easy via WebCal software and USB adapter
- Narrow 2 inch beam width and short 4 inch dead band optimized for small tanks
- Four programmable relays for switch, pump or valve control and fail-safety
- 1 pump or valve with 3 alarms
- 2 pumps (lead-lag) with 2 alarms
- pumps (duplexing) with 2 alarms
- 4 independent switch point alarms
- PVDF transducer and 6P polycarbonate enclosure for corrosive liquids
- Automatic temperature compensation for accurate measurement
- Provides switch, controller, and transmitter functions in one device
| Range | 9.8ft (3m) |
|---|---|
| Accuracy | +/- 0.2% of range |
| Resolution | 0.039 |
| Dead band | 4 |
| Beam width | 2in (5cm) |
| Configuration | WebCal PC Windows USB 2.0 |
| Memory | Non-volatile |
| Supply voltage | 24 VDC (loop) |
| Consumption | 0.5W |
| Loop resist. | 400Ω max |
| Signal output | 4-20 mA, two-wire |
| Signal invert | 4-20 mA or 20-4 mA |
| Signal fail-safe | 4 mA, 20 mA, 21 mA, 22 mA or hold last |
| Contact type | SPST relays |
| Contact rating | 60 VA, 1A maximum |
| Contact fail-safe | Power loss: Hold last Echo loss: Open, close or hold last |
| Hysteresis | Selectable |
| Process temp. | F: -4° to 140°, C: -20° to 60° |
| Temp. comp. | Automatic |
| Ambient temp. | F: -31° to 140°, C: -35° to 60° |
| Pressure | MWP = 30 PSI (2 bar) |
| Enclosure rating | ype 6P, encapsulated, corrosion resistant & submersible |
| Enclosure mat. | Polycarbonate |
| Trans. material | PVDF |
| Cable jacket | Polyurethane |
| Cable type | 9-conductor, shielded |
| Cable length | 48in (1.2m) |
| Process mount | 1in NPT (1in G) |
| Mount gasket | Viton |
| Classification | General purpose |
| Compliance | CE, RoHS |
| Approvals | cFMus |