Flowline AU13-1114 Level Controller AU13-1114

Flowline AU13-1114 Level Controller AU13-1114

Switch-Pro Flowline with Consumption 0.25A maximum
SKU:AU13-1114
Model Number: AX13-X1XX
$1120.000

Flowline AU13-1114 Switch-Pro with Compact Level Controller. Sensor technology Ultrasonic, Wetted material PP/Ryton, Configuration Controller with Strobe Alert


WHERE TO BUY?
Overview
Specification
Documents
Accessories
Overview
Application

Intended for side wall installation, the general purpose level switch package provides reliable liquid level detection with a 16A compact level controller for pump or valve control. The optional flash alarm brings attention to alarm conditions. Offered in two level sensor technologies, select the type and material based upon your application media. This liquid level switch package is widely applied in bulk storage and process tank level applications for high level control or low level control.

Ultrasonic Level Sensor : Broadly applied in chemicals and light weight oils

Vibration Level Sensor : Applied in wastewater with light coating or scaling

Buoyancy Level Sensor : Applied in clean water and non-coating chemicals

Features:
  • Rugged polypropylene, Ryton or PFA sensor for corrosive liquid applications
  • Fail-safe relay control of pumps or valves with 0-60 second delay
  • Polypropylene enclosure rated NEMA 4X with swivel base for conduit alignment
  • Optional strobe brings immediate attention to level alarm conditions
  • Invert switch changes relay state from NO to NC without rewiring
  • Offered in 2 sensing technologies for broad application coverage: ultrasonic & vibration
Specification
Accuracy±1mm in water
Repeatability±0.5mm in water
LED IndicationSensor, Power & Relay
Supply voltage120 / 240 VAC @ 50-60 Hz
Consumption0.25A Max
Contact Type(1) SPST relay
Contact Rating250 VAC @ 10A
Contact OutputSelectable NO/NC
Contact Delay0-60 seconds
Process Temperature-40°F to 176°F (-40°C to 80°C)
Ambient Temperature-40°F to 140°F (-40°C to 60°C)
Pressure150 psi (10 bar) @ 25° C, derated @ 1.667 psi (0.113 bar) per °C above 25º C
Enclosure ratingNEMA 4X (IP65)
Conduit Entrance1/2in NPT
Process Mount3/4in NPT (3/4in G)
Mount GasketViton
ClassificationGeneral purpose
ComplianceCE
TypeLevel Controller
SeriesAX13
Documents

Related Documents List

Accessories
LM52-2400 Flowline Fittings LM52-2400
LM52-2800 Flowline Installation Fittings LM52-2800
LM52-2410 Flowline Fittings LM52-2410
LM52-3410 Flowline Fittings LM52-3410
LM52-2810 Flowline Fittings LM52-2810
LM52-2890 Flowline Fittings LM52-2890
LM52-2850 Flowline Fittings LM52-2850
LM50-1001 Flowline Fittings LM50-1001